Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Ethylbenzene
CAS # 100-41-4
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
106.1650
Formula
C
8
H
10
Melting Point
-95 °C, 178 °K, -139 °F
Boiling Point
136 °C, 409 °K, 277 °F
Density
0.8665 g/mL
Solubility in Water
0.015 g/100 mL (20 °C)
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Ethylbenzene; Benzene, ethyl-; Ethylbenzol; EB; Phenylethane; Aethylbenzol; Ethylbenzeen; Etilbenzene; Etylobenzen; NCI-C56393; α-Methyltoluene; UN 1175; NSC 406903; Ethylbenzène
Related Products
Residual Solvents Class 2 – Mix A (2020 Rev), 0.35-22.5 mg/mL in DMSO (dimethylsulfoxide), 1 mL/ampul
8260 MegaMix Calibration Mix, 2000 µg/mL in P&T Methanol, 1 mL/ampul
DL152/06 Aromatic Compounds Standard, 1000 µg/mL, P&T Methanol, 1 mL/ampul
624 Volatile Organics Kit
DW-VOC Standard #2, 200 µg/mL, P&T Methanol, 1 mL/ampul
Gasoline Component Standard, 10,000 µg/mL total in P&T Methanol, 1 mL/ampul
VOA Calibration Mix #2, 2000 µg/mL, P&T Methanol, 1 mL/ampul
BTEX Standard, 2000 µg/mL, P&T Methanol (m- & p-Xylene at 1000 µg/mL), 1 mL/ampul
Michigan GRO Mix, 2000 µg/mL, P&T Methanol, 1 mL/ampul
Volatiles MegaMix Standard, EPA Method 624, 2000 µg/mL, P&T Methanol, 1 mL/ampul
PVOC Mix (California), 1000 µg/mL, P&T Methanol, 1 mL/ampul
8260 MegaMix Calibration Mix Kit, P&T Methanol, 2 ampuls/kit
502.2 VOA Calibration Kit #1 (2000 µg/mL)
BTEX Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
8020A Calibration Mix, 2000 µg/mL, P&T Methanol, 1 mL/ampul
DW-VOC Standard #2A, 2000 µg/mL, P&T Methanol, 1 mL/ampul
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
LC Performance Test Mix, Methanol, 1 mL/ampul
8260A Volatile Organics Kit (2000 µg/mL)
Airgas Standard, BTEX Gas Mix, 1 ppm in N2, 124 L @ 1800 psig
PA DEP UST Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
WA VPH Standard, 1000 µg/mL, P&T Methanol, 1 mL/ampul
DW-VOC Kit #2 (500 series), 2000 µg/mL
Atlantic RBCA VPH Mix, 1000 µg/mL, P&T Methanol, 1 mL/ampul
Application Chromatograms
Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
Determination Of Hydrocarbon Group Type in Gasoline on Rxi-1ms by GC-VUV (ASTM D8071)
PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Cumene (Isopropylbenzene) on Rtx-1
Impurities in α-Methylstyrene on Rtx-1
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
Impurities in
p-
Xylene on Stabilwax
Styrene on Stabilwax
Ethylbenzene on Stabilwax
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Aromatics on Rtx-DHA-100 (ASTM D6729-14)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Residual Solvents Class 2 - Mix A (2013 Rev) on Stabilwax (G16)
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
Residual Solvents Class 2 — Mix A on Rxi-624Sil MS (G43) by USP <467>
PAMS 57 Component Mix on Rtx-1 (105 m)
Cannabis Residual Solvents at 50 ppm Cutoff
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Food Packaging Volatiles by Purge & Trap GCMS on Rtx-5MS, Overwrap, No Seam
Aromatics (Benzene/Toluene/Xylene) on Rtx-200
Aromatics (Benzene/Toluene/Xylene) on MXT-WAX
Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2
Aromatics (Benzene/Toluene/Xylene) on Rtx-Wax
BTEX on Rtx-502.2
Volatile Organics (Canada) on Rtx-VMS
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
Reformate on Rtx-1
Alaska Method AK101AA on Rtx-5Sil MS (PID)
Alaska Method AK101AA on Rtx-5Sil MS (FID)
Gasoline Aromatics on Rtx-1
Petroleum Oxygenates on Stabilwax
Gasoline Aromatics on Rtx-1
EPA Method 524.2, Revision 4 Rtx-VMS
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
SRM 870 Test Mix on Viva C18
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
p-
and
m-
Xylenes in Gasoline by GCxGC on Rtx-DHA-150 and Stabilwax
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Solvents on Rt-QS-BOND
Styrene Impurities on Stabilwax
Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS, Overwrap at the Seam
Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS
EPA Method 524.2 on Rtx-502.2
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
Wisconsin GRO Mix, plus C12 on Rtx-502.2
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Styrene Impurities Rtx-1701
Competitor Comparison: Class 2 - Mix A Residual Solvents for USP <467> Water-Soluble Articles
Aromatics on Rt-TCEP
Mass APH on Rxi-1ms
Aromatics, Aliphatics on 10 TCEP 100/120 Chromosorb PAW
Volatiles US EPA Method 624 on Rtx-624
Aromatics (Xylene Isomers plus Cumene) on 5 RT-1200/1.75 Bentone 34 on 100/120 Silcoport
Aromatics (Xylene Isomers /BTEX) on 5 Rt-1200/5 Bentone 34 on 100/120 Silcoport
Detailed Hydrocarbons Analysis Rtx-DHA-100
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents (Class 2 - Mixture A) on Stabilwax (G16)
Residual Solvents Rxi-624Sil MS
Ozone Precursors on Rtx-1
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Volatile Petroleum Hydrocarbons (VPH) Massachusetts Department of Environmental Protection on Rtx-502.2
Solvent Mixture on Rt-Q-BOND
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
Residual Solvents (Class 2 - Mixture A) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix A Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS