Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Methyl tert-butyl ether
CAS # 1634-04-4
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
88.1482
Formula
C
5
H
12
O
Melting Point
-109 °C, 164 °K, -164 °F
Boiling Point
55.2 °C, 328 °K, 131 °F
Density
0.7404 g/cm³
Solubility in Water
26 g/L (20 °C)
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Propane, 2-methoxy-2-methyl-; Ether, tert-butyl methyl; tert-Butyl methyl ether; Methyl tert-butyl ether; 2-Methoxy-2-methylpropane; 2-Methyl-2-methoxypropane; tert-C4H9OCH3; Methyl t-butyl ether; MTBE; Methyl 1,1-dimethylethyl ether; Driveron; methyl tert-butyl ether (MTBE); 1,1-Dimethylethyl methyl ether; t-Butyl methyl ether; Méthyl tert-butyl éther; Metil-ter-butil-etere
Related Products
Residual Solvents Class 3 – Mix A (2020 Rev), 5000 µg/mL in N,N-DMF (N,N-dimethylformamide), 1 mL/ampul
DL152/06 Aromatic Compounds Standard, 1000 µg/mL, P&T Methanol, 1 mL/ampul
Michigan GRO Mix, 2000 µg/mL, P&T Methanol, 1 mL/ampul
PVOC Mix (California), 1000 µg/mL, P&T Methanol, 1 mL/ampul
Residual Solvents Class 3 - Mix A, 5000 µg/mL each in N,N-Dimethylformamide, 1 mL/ampul
Methyl-Tert-Butyl Ether (MTBE) Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
Oxygenates Standard (6 Components), P&T Methanol, 1 mL/ampul
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
524 Calibration Mix #8, 2000 µg/mL, P&T Methanol, 1 mL/ampul
PA DEP UST Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
WA VPH Standard, 1000 µg/mL, P&T Methanol, 1 mL/ampul
524.3 VOA MegaMix Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
MA VPH Matrix Spike Mix with Surrogate, 2500 µg/mL, P&T Methanol, 1 mL/ampul
California Oxygenates Mix, P&T Methanol, 1 mL/ampul
Volatile MegaMix II, 2000-10,000 µg/mL in P&T Methanol, 1 mL/ampul
CLP 04.1 VOA Kit #3
CA WIP VOA Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
CLP 04.1 VOA CAL2000 MegaMix Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
MA VPH Standard with Surrogate Rev. 1.1 (July 2004), 10,000 µg/mL in P&T Methanol, 1 mL/ampul
OLC 03.2 VOA MegaMix Standard, 2000 µg/mL each in P&T Methanol (m-Xylene and p-Xylene at 1000 µg/mL), 1 mL/ampul
524 Rev. 4.0 VOA Kit #2 (2000 µg/mL)
MA Volatile Petroleum Hydrocarbon (VPH) Standard, P&T Methanol, 1mL/ampul
PVOC/GRO Mix (Wisconsin), 1000 µg/mL, P&T Methanol, 1 mL/ampul
524 Rev. 4.0 Volatile Organics Kit (2000 µg/mL)
Application Chromatograms
Analysis of VOCs and Odors in Drinking Water via HS-SPME Arrow-GC-MS
Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Hexane, MTBE, and TBA on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
USP <467> Residual Solvents Class 3 MIx A on Rxi-624Sil MS
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Oxygenates on Rtx-VMS
Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2
Petroleum Oxygenates (MTBE) on Rtx-1
Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Gasoline Range Organics Oxygenates Rtx-VMS
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Petroleum Oxygenates on Rt-TCEP
Mass APH on Rxi-1ms
Detailed Hydrocarbons Analysis Rtx-DHA-100
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Volatile Petroleum Hydrocarbons (VPH) Massachusetts Department of Environmental Protection on Rtx-502.2
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)