Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Tridecane
CAS # 629-50-5
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
184.3614
Formula
C
13
H
28
Melting Point
-6--4 °C, 267-269 °K, 21-25 °F
Boiling Point
232-236 °C, 505-509 °K, 449-457 °F
Density
0.756 g mL
−1
log P
7.331
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Tridecane; n-Tridecane; Tridecane, n-; C13
Related Products
MOSH/MOAH Standard, 150-600 µg/mL, Toluene, 1 mL/ampul
Qualitative Retention Time Index Standard, In Hexane, 1 mL/ampul
MOSH/MOAH Retention Time Standard, 100 µg/mL, Cyclohexane, 1 mL/ampul
DRO Mix (Tenn/Miss), 1000 µg/mL, Methylene Chloride, 1 mL/ampul
XIL-350 Column Test Mix, 350 µg/mL ea. in Methylene Chloride, 1 mL/ampul
Rxi Test Mix (Rev. A), 1000 µg/mL, Toluene, 1 mL/ampul
Rxi Test Mix (250 ppm), 250 µg/mL, Toluene, 1 mL/ampul
D3710-95 Calibration Mix, 1 mL/ampul
NPI-1000 Column Test Mix, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Kovats Test Mix #3, 250 µg/mL, Methylene Chloride, 1 mL/ampul
XERT-500 Column Test Mix, 500 µg/mL, Toluene, 1 mL/ampul
ISO-BB Column Test Mix, 250 µg/mL ea. in Methylene Chloride, 1 mL/ampul
NPI-350 Column Test Mix, 350 µg/mL ea. in Methylene Chloride, 1 mL/ampul
Application Chromatograms
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
Quality Control Test Mix on Rxi-1301Sil MS
Solvent Mixture #1 on Rtx-1
Solvent Mixture #1 on Rtx-200
Solvent Mixture #1 on Stabilwax
Solvent Mixture #2 on Rtx-1
Solvent Mixture #2 on Rtx-200
Solvent Mixture #2 on Stabilwax
Solvent Mixture #3 on Rtx-1
Solvent Mixture #3 on Rtx-200
Crude Oil, Arabian Light on Rtx-1
Crude Oil, Prudhoe Bay on Rtx-1
Solvent Mixture #3 on Stabilwax
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
Low Bleed, High Efficiency MXT-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
Isothermal Test Mix on Rxi-5ms
Rxi-5ms columns have the lowest bleed among all major brands of columns.
Petroleum Oxygenates on Rt-TCEP
Hydrocarbons (C7-C42) on Rtx-1
Detailed Hydrocarbons Analysis Rtx-DHA-100
Column Test Mix on Rxi-5Sil MS
Bleed Profiles of 5HT Columns
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
Batch-to-Batch Reproducibility of Rxi-5Sil MS