Tetracosane
CAS # 646-31-1
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
338.6538
Formula
C
24
H
50
Melting Point
48-54 °C, 321-327 °K, 118-129 °F
Boiling Point
391 °C, 664.5 °K, 736 °F
Solubility in Water
not soluble
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Tetracosane; n-Tetracosane; C24; tetrakosane
Related Products
MA EPH Aliphatic Hydrocarbon Standard, 1000 ug/mL, Hexane, 1 mL/ampul
Florida TRPH Standard (HC), 2000 ug/mL, Carbon Disulfide, 1 mL/ampul
OQ Response Linearity Test Standard, Isooctane, 1 mL/ampul
System Performance Test Standard Mixture of n-Alkanes, 50 ug/mL, Hexane, 1 mL/ampul
DRO/ORO Range Calibration Standard, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
NJDEP EPH 10/08 Rev.2 Aliphatics Fractionation Check Mix, 400 ug/mL, Hexane, 5 mL/ampul
Florida TPH Standard, 500 ug/mL, Hexane, 1 mL/ampul
Leaking Underground Storage Tank (LUST) Retention Time Standard, 25 ug/mL, Methylene Chloride, 1 mL/ampul
Qualitative Retention Time Index Standard, In Hexane, 1 mL/ampul
DRO Mix (Tenn/Miss), 1000 ug/mL, Methylene Chloride, 1 mL/ampul
NJDEP EPH 10/08 Rev.2 Aliphatics Matrix Spike Mix, 200 ug/mL, Pentane, 5 mL/ampul
NJDEP EPH 10/08 Rev.2 Aliphatics Calibration Standard, 2000 ug/mL, Hexane:Carbon Disulfide (80:20), 1 mL/ampul
DRO Mix (EPA/Wisconsin), 2000 ug/mL, Methylene Chloride, 1 mL/ampul
MA Fractionation Check Mix, 25 ug/mL, Hexane, 1 mL/ampul
Standard Mixture of n-alkanes for System Performance Test, 50 ug/mL, Cyclohexane, 1 mL/ampul
ASTM D2887-12 Calibration Standard, 1% w/w in Carbon Disulfide, 1 g solution/ampul
D2887 Calibration Mix, 1 mL/ampul
Connecticut ETPH Calibration Mix, Methylene Chloride, 1 mL/ampul
MOSH/MOAH Retention Time Standard 100 µg/mL, Cyclohexane, 1 mL/ampul
Application Chromatograms
Petroleum Hydrocarbons (TPH) on Rxi-1ms
NJ DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
MA DEP EPH Aliphatics on Rxi-5Sil MS
NJ DEP EPH Aliphatics on Rxi-5Sil MS
MA DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
Simulated Distillation on Rtx-1 SimDist DiatoSorb-WHP by ASTM D2887
Diesel #2/Motor Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Diesel #2/Motor Oil Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard Mix on Rxi-1HT
Petroleum Wax on MXT-1
Crude Oil, Arabian Light on Rtx-1
Crude Oil, Prudhoe Bay on Rtx-1
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
C10-C40 Alkanes on Rxi-5HT
Low Bleed, High Efficiency MXT-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
n-
Alkanes on Rtx-Mineral Oil
Hydrocarbons (C7-C42) on Rtx-1
n-
alkanes (C10-C40) on Rtx-Mineral Oil
DRO Mix on Rtx-5
Simulated Distillation (C5-C44) on Rtx-2887
NJDEP EPH Aliphatic Fraction on Rtx-5