mevinphos

CAS # 7786-34-7

Compound Structure and Properties

Molecular Weight224.1483
FormulaC7H13O6P
Data above sourced from: ChemSpider

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Mevinphos; CMDP; Fosdrin; Gesfid; Meniphos; Phosdrin; PD 5; cis-Phosdrin; Compound 2046; ENT 22,374; Gestid; Menite; Mevinfos; OS 2046; Phosfene; Apavinphos; Duraphos; Mevinox; Mevinphos mixture; Mevinphos α; Mevinphos β; Mevinphos (α+β); Mevinphos-cis; Mevinphos-trans; 2-Butenoic acid, 3-[(dimethoxyphosphinyl)oxy]-, methyl ester; Crotonic acid, 3-hydroxy-, methyl ester, dimethyl phosphate; 2-Carbomethoxy-1-Methylvinyl dimethyl phosphate; 2-Methoxycarbonyl-1-methylvinyl dimethyl phosphate; (α-2-Carbomethoxy-1-methylvinyl) dimethyl phosphate; (cis-2-Methoxycarbonyl-1-methylvinyl) dimethyl phosphate; (2-Methoxycarbonyl-1-methyl-vinyl)-dimethyl-fosfaat; (2-Methoxycarbonyl-1-methyl-vinyl)-dimethyl-phosphat; (2-Metossicarbonil-1-metil-vinil)-dimetil-fosfato; Dimethyl (1-methoxycarboxypropen-2-yl)phosphate; Dimethyl (2-methoxycarbonyl-1-methylvinyl) phosphate; Dimethyl methoxycarbonylpropenyl phosphate; Dimethyl phosphate of methyl 3-hydroxy-cis-crotonate; Dimethyl-1-carbomethoxy-1-propen-2-yl phosphate; Methyl 3-(dimethoxyphosphinyloxy)crotonate; O,O-Dimethyl O-(1-methyl-2-carboxyvinyl) phosphate; O,O-Dimethyl-O-(2-carbomethoxy-1-methylvinyl) phosphate; 2-Carbomethoxy-1-methylvinyl dimethyl phosphate, α isomer; 2-Carbomethoxy-1-propen-2-yl dimethyl phosphate; 3-Hydroxycrotonic acid methyl ester dimethyl phosphate; 3-((Dimethoxyphosphinyl)oxy)-2-butenoic acid methyl ester; O,O-Dimethyl-O-2-methoxycarbonyl-1-methyl-vinyl-phosphat; 1-Methoxycarbonyl-1-propen-2-yl dimethyl phosphate; Methyl (2E)-3-[(dimethoxyphosphoryl)oxy]-2-butenoate; α-Mevinphos

Related Products

Application Chromatograms

Low-Level Pesticides in Cannabis Flower on RMX-5Sil MS by GC-MS/MS
GC Multiresidue Pesticide Standards Kit on Rxi-5ms
Fast Analysis of QuEChERS Performance Standards Kit on LPGC Rtx-5ms (10 m)
Comparison of Conventional and LPGC-MS Analysis of QuEChERS Performance Standards
New York Pesticides on Raptor ARC-18 by LC-MS/MS
New York Pesticides on Rxi-5ms
Canadian Pesticides on Rxi-5ms
California Cannabis Pesticides and Mycotoxins in Chocolate on Raptor ARC-18
200+ Pesticides in Strawberry on Low-Pressure GC Column Kit
California Cannabis Pesticides and Mycotoxins in Gummy Edibles on Raptor ARC-18