Butanone
CAS # 78-93-3
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
72.1057
Formula
C
4
H
8
O
Melting Point
-86 °C, 187 °K, -123 °F
Boiling Point
79.64 °C, 353 °K, 175 °F
Density
0.8050 g/cm
3
Solubility in Water
27.5 g/100 mL
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
2-Butanone; Butan-2-one; Butanone; Ethyl methyl ketone; Ketone, methyl ethyl; Methyl ethyl ketone; MEK; C2H5COCH3; Acetone, methyl-; Aethylmethylketon; 3-Butanone; Butanone 2; Ethyl methyl cetone; Ethylmethylketon; Ketone, ethyl methyl; Meetco; Methyl acetone; Metiletilchetone; Metyloetyloketon; Rcra waste number U159; 2-Oxobutane; Meketone; Oxobutane; 2-butanone (MEK; 2-butanal; 2-butanone (MEK); UN 1193; 2-Butanone (MEC)
Related Products
Residual Solvents Class 3 – Mix A (2020 Rev), 5000 µg/mL in N,N-DMF (N,N-dimethylformamide), 1 mL/ampul
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
Inter-Polar Column Test Mix, Methylene Chloride, 1 mL/ampul
524 Calibration Mix #7 Kit
CLP 04.1 VOA Kit #3
2-Butanone (MEK) Standard, 5000 µg/mL, P&T Methanol/Water (90:10), 1 mL/ampul
Residual Solvents Class 3 - Mix A, 5000 µg/mL each in N,N-Dimethylformamide, 1 mL/ampul
Blood Alcohol Mix, Resolution Control Standard, 0.100 g/dl, Water, 1 mL/ampul
524 Rev. 4.0 Volatile Organics Kit (2000 µg/mL)
524 Rev. 4.0 VOA Kit #2 (2000 µg/mL)
TCLP VOA Mix, 2000 µg/mL, P&T Methanol:Water (90:10), 1 mL/ampul
524 Calibration Mix #7A, 2000 µg/mL each in P&T methanol:water (90:10), 1 mL/ampul
VOA Calibration Mix #1 (Ketones), 5000 µg/mL, P&T Methanol:Water (90:10), 1 mL/ampul
Ketones Mix, 524.2 Rev. 4.1, 90% P&T Methanol:10% Water, 1 mL/ampul
Application Chromatograms
Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
Spark Ignition Fuel with Butanol Impurities on D3606 Application Column Set by ASTM D3606-20
Solvents on Rt-U-BOND
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
USP <467> Residual Solvents Class 3 MIx A on Rxi-624Sil MS
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Solvents on DiatoSorb-WHP Packed Column
CARB 1004 Aldehyde/Ketone-DNPH Calibration Standard on Raptor ARC-18
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics TO-15 Volatiles on Rtx-1
Custom Solvents Mix on Stabilwax-MS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Alcohols and Acetates on Stabilwax-MS
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
Solvents on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Solvents on Rtx-5
Solvents on Stabilwax
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Ketones on Rt-QS-BOND
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Microbial VOCs on Rxi-1ms
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)