CAS # 85-01-8
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
178.2292
Formula
C
14
H
10
Melting Point
101 °C, 374 °K, 214 °F
Boiling Point
332 °C, 605 °K, 630 °F
Density
1.18 g/cm
3
Solubility in Water
1.6 mg/L
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Phenanthrene; Phenanthren; Phenanthrin; Phenantrin; Phénanthrène; Fenantrene; Phenantrene
Related Products
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
DL152/06 PAH Standard, 200 μg/mL, Methylene Chloride, 1 mL/ampul
8270/Appendix IX Kit
SV Calibration Mix #5, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
NJDEP EPH 10/08 Rev.2 Aromatics Calibration Standard, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Calibration Mix #5, Revised, 2000 µg/mL ea. in Methylene Chloride, 1 mL/ampul
SOM01.1 SVOA MegaMix Standard Kit
SVOC MegaMix 100 Kit, 1 mL/ampul; 3 ampuls/kit
WA EPH Aromatic Hydrocarbon Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
NJDEP EPH 10/08 Rev.2 Aromatics Fractionation Check Mix, 400 µg/mL, Hexane:Toluene (50:50), 5 mL/ampul
EPA Method 8310 Quality Control Check, Acetonitrile, 1 mL/ampul
MA EPH Aromatic Hydrocarbon Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
CLP 04.1 B/N MegaMix Standard, Revision 2, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Phenols/Anilines/Pesticides Test Mix, 50 µg/mL, Methylene Chloride, 1 mL/ampul
Semivolatile Calibration Kit #3 (with Benzidine)
610 PAH Calibration Mix B, Methylene Chloride:Methanol 50:50, 1 mL/ampul
Phenanthrene Standard, 1000 µg/mL, Methanol, 1 mL/ampul
8270 Calibration Kit, 2000 µg/mL
NJDEP EPH 10/08 Rev.2 Aromatics Matrix Spike Mix, 200 µg/mL, Acetone:Toluene (50:50), 5 mL/ampul
EPA Method 8310 PAH Mix, 500 μg/mL, Acetonitrile/Toluene (92:8), 1 mL/ampul
Method 525.2 Semivolatile Mix (revised), Acetone, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
Application Chromatograms
EU Monitored PCBs and PAHs on Rxi-XLB
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Priority PAH Pollutants on Rxi-SVOCms (SIM)
Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar on Rxi-SVOCms (SIM)
Semivolatiles Analysis on Rxi-SVOCms
MA DEP EPH Aromatics on Rxi-5Sil MS
NJ DEP EPH Aromatics on Rxi-5Sil MS
MA DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
NJ DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
Select PAHs on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)
Semivolatiles on Rxi-5ms (Split Injection)
EPA 8310 PAHs on Pinnacle II PAH by LC-UV
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH (30 m x 0.25 mm ID x 0.10 µm df )
NIST SRM 1975, Diesel Particulate Extract, on Rxi-PAH
Accelerated Solvent Extraction of NIST SRM 1941b, Organics in Marine Sediment, on Rxi-PAH
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
NIST SRM 2260a PAH Mix on Rxi-PAH
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-CLPesticides2
Polynuclear Aromatic Hydrocarbons US EPA Method 8100 on MXT-5
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-5
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-440
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Phenanthrene and Anthracene on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
PAHs and PCB Congeners on Rxi-XLB
Stir Bar Sorptive Extraction Cleaned Up Sample - QuEChERS Extract of NIST SRM Mussel (Rxi-17Sil MS and Rxi-1ms, m/z 178)
EPA 8310 PAH Mix on Pinnacle II PAH (FLD)
EPA 8310 PAH Mix on Pinnacle DB PAH
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Comparison of 2,4-Dinitrophenol response with Semivolatiles wool and MS Certified wool
Polycyclic Aromatic Hydrocarbons on Rtx-50
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS
Polycyclic Aromatic Hydrocarbons on Rxi-17
Polycyclic Aromatic Hydrocarbons on Rxi-17 column
Polycyclic Aromatic Hydrocarbons on Rxi-17 (15m x 0.25mm x 0.25µm)
Phenanthrene and Anthracene on Rxi-17 (15m x 0.25mm x 0.25µm)
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
Polycyclic Aromatic Hydrocarbons by EPA Method 610 on Rxi-5ms
Semivolatiles on Rxi-5ms by EPA Method 525.2
EPA Method 610 Polycyclic Aromatic Hydrocarbons on Pinnacle DB PAH
QuEChERS Extract of NIST SRM 2974a Freeze-Dried Mussel Tissue (GCxGC contour plot)
NJDEP EPH Aromatics on Rtx-5
Polycyclic Aromatic Hydrocarbons by EPA 610 on Rxi-5ms
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS