Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Hexachlorobutadiene
CAS # 87-68-3
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
260.7608
Formula
C
4
Cl
6
Melting Point
-22 - -19 ℃
Boiling Point
210-220 ℃
Density
1.665 g/mL at 25 ℃
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
C 46; Hexachloro-1,3-Butadiene; Hexachlorobutadiene; Perchlorobutadiene; Hexachlorobutadiene-(1,3); Gp-40-66:120; Hexachlor-1,3-butadien; Hexachlorbutadiene; HCBD; 1,3-Butadiene, hexachloro-; Dolen-pur; 1,3-Hexachlorobutadiene; Rcra waste number U128; Perchloro-1,3-butadiene; Butadiene, hexachloro-; Hcb; Hexachloro-1,3-butadiène; Esacloro-1,3-butadiene
Related Products
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
8260 MegaMix Calibration Mix, 2000 µg/mL in P&T Methanol, 1 mL/ampul
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
DL152/06 Aliphatic Compounds-Mix 2, 100 µg/mL, P&T Methanol, 1 mL/ampul
Semivolatile Calibration Kit #3 (with Benzidine)
8270 Calibration Kit, 2000 µg/mL
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
8260 MegaMix Calibration Mix Kit, P&T Methanol, 2 ampuls/kit
8270/Appendix IX Kit
502.2 VOA Calibration Kit #1 (2000 µg/mL)
CLP 04.1 B/N MegaMix Standard, Revision 2, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
TCLP B/N Method 1311 Standard, 2000 µg/mL, Acetone, 1 mL/ampul
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
8260A Volatile Organics Kit (2000 µg/mL)
Semivolatiles MegaMix Standard, EPA Method 625, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
SVOC MegaMix 100 Kit, 1 mL/ampul; 3 ampuls/kit
8270 Calibration Mix #3, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
502.2 MegaMix Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
524.3 VOA MegaMix Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
502.2 Calibration Mix #6, 2000 µg/mL, P&T Methanol, 1 mL/ampul
8270 B/N Calibration Check Mix, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
8260 MegaMix Calibration Mix, Revised, 2000 µg/mL in P&T Methanol, 1 mL/ampul
SOM01.1 SVOA MegaMix Standard, Revised, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Application Chromatograms
EPA 8270E Semivolatiles on RMX-5Sil MS by GC-MS/MS (Shimadzu Chromatogram)
Semivolatiles on RMX-5Sil MS by 8270D (GC-MS in SIM Mode)
Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
EPA Method 524.2 on Rtx-502.2
Low Bleed, High Efficiency MXT-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Semivolatiles CLP Method on Rtx-5MS