Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
4-Aminobiphenyl
CAS # 92-67-1
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
169.2224
Formula
C
12
H
11
N
Melting Point
52−54 °C
Boiling Point
302 °C
Density
1,16 g·cm
−3
Solubility in Water
practically insoluble in water
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
[1,1'-Biphenyl]-4-amine; 4-Biphenylamine; p-Aminobiphenyl; p-Aminodiphenyl; p-Biphenylamine; p-Phenylaniline; p-Xenylamine; Aniline, p-phenyl-; Xenylamine; 4-Aminobiphenyl; 4-Aminodiphenyl; 4-Biphenylylamine; 4-Phenylaniline; biphenyl-4-ylamine; Biphenylamine; Xenylamin; 4-Aminodifenil; 4-Aminobifenyl; 4-Bifenylamin; Paraaminodiphenyl
Related Products
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
8270/Appendix IX Kit
Appendix IX Mix #1, Revised, 2000 µg/mL ea. in Methylene Chloride, 1 mL/ampul
Application Chromatograms
Customer Analysis of Aryl Amines on LPGC Rxi-35Sil MS
Comparison of Conventional and LPGC-MS Analysis of REACH Carcinogenic Arylamines
Conventional GC-MS Analysis of REACH Carcinogenic Arylamines on Rxi-35Sil MS
Fast GC-MS Analysis of REACH Carcinogenic Arylamines on LPGC Rxi-35Sil MS
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Regulated Carcinogenic Aryl Amines Resulting From Reductive Cleavage of Azo Dyes on Rxi-35Sil MS
High Speed GC-MS of Carcinogenic Aryl Amines Resulting From Reductive Cleavage of Azo Dyes on Rxi-35Sil MS (Scan Mode)
High Speed GC-MS-SIM of Carcinogenic Aryl Amines Resulting From Reductive Cleavage of Azo Dyes on Rxi-35Sil MS (SIM Mode)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270