Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Benzyl alcohol
CAS # 100-51-6
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
108.1378
Formula
C
7
H
8
O
Melting Point
-15 °C, 258 °K, 5 °F
Boiling Point
205 °C, 478 °K, 401 °F
Density
1.044 g cm
−3
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Benzyl Alcohol; Benzenemethanol; α-Hydroxytoluene; α-Toluenol; (Hydroxymethyl)benzene; Benzenecarbinol; Phenylcarbinol; Phenylmethanol; Phenylmethyl alcohol; Methanol, phenyl-; NCI-C06111; Hydroxytoluene; Bentalol; Benzoyl alcohol
Related Products
8270 MegaMix Standard, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
SV Calibration Mix #1, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
LC Normal Phase Test Mix #1, Hexane, 1 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
8270/Appendix IX Kit
8270 Calibration Kit, 2000 ug/mL
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit
Fragrance Allergen Standards Kit
Semivolatile Calibration Kit #3 (with Benzidine)
8270 Calibration Mix #4, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
Application Chromatograms
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Solvent Mixture #1 on Rtx-1
Solvent Mixture #1 on Rtx-200
Solvent Mixture #1 on Stabilwax
Solvent Mixture #2 on Rtx-1
Solvent Mixture #2 on Rtx-200
Solvent Mixture #2 on Stabilwax
Solvent Mixture #3 on Rtx-1
Solvent Mixture #3 on Rtx-200
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Flavor Compounds in Grappa on Stabilwax-DA
Petroleum Oxygenates on Stabilwax
Solvent Mixture #3 on Stabilwax
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Peak Shape Comparison of Early Eluting Semivolatiles Using Split (10:1) and Splitless Injection at 80 °C Oven Start Temp.
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Mushroom Aroma (Synthetic) on Stabilwax
Semivolatiles CLP Method on Rtx-5MS
Fragrance Allergens on Rxi-1ms & Rxi-17 (GC x GC)