EZGC & EZLC Online Software Suite

1,4-Dichlorobenzene

CAS # 106-46-7

Compound Structure and Properties

Molecular Weight147.0020
FormulaC6H4Cl2
Melting Point53.5 °C, 327 °K, 128 °F
Boiling Point174 °C, 447 °K, 345 °F
Density1.25 g/cm³, solid
Solubility in Water10.5 mg/100 mL (20 °C)
Data above sourced from: ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Benzene, 1,4-dichloro-; Benzene, p-dichloro-; p-Chlorophenyl chloride; p-Dichlorobenzene; Di-chloricide; Evola; Paradi; Paradow; Paramoth; Persia-Perazol; PDB; Santochlor; 1,4-Dichlorobenzene; Di-Choricide; p-Dichlorobenzol; Paradichlorobenzol; para-Dichlorobenzene; p-Dichloorbenzeen; p-Dichlorbenzol; p-Diclorobenzene; Dichlorobenzene; Dichlorobenzene, p-; NCI-C54955; para crystals; Paracide; Paranuggets; Parazene; PDCB; 1,4-Dichloorbenzeen; 1,4-Diclorobenzene; Dichlorobenzene, para; Globol; Paradichlorbenzol; Rcra waste number U070; Rcra waste number U071; Rcra waste number U072; 1,4-Dichlorobenzene paste; p-DCB; Dichlorocide; Kaydox; p-Dichlorbenzene; PARA; 1,4-Dichlorbenzol; 1,4-Dichlor-benzol; UN 1592; NSC 36935; 1,4-chlorobenzene; 1,4-Dichlorobenzène

Related Products

8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
8260 MegaMix Calibration Mix, 2000 µg/mL in P&T Methanol, 1 mL/ampul
DL152/06 Chlorobenzenes Standard, 100 µg/mL, P&T Methanol, 1 mL/ampul
524.3 VOA MegaMix Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
Drinking Water VOA MegaMix Standard, 524.2 Rev. 4.1, 2000 µg/mL, P&T Methanol, 1 mL/ampul
VOA Purgeable Halocarbon Mix #1, 2000 µg/mL, P&T Methanol, 1 mL/ampul
DW-VOC Kit #2 (500 series), 2000 µg/mL
SV Calibration Mix #7, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
502.2 MegaMix Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul

Application Chromatograms

Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)