Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
M-Xylene
CAS # 108-38-3
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
106.1650
Formula
C
8
H
10
Melting Point
-48 °C, 225 °K, -54 °F
Boiling Point
139 °C, 412 °K, 282 °F
Density
0.86 g/mL
Solubility in Water
insoluble
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Benzene, 1,3-dimethyl-; m-Xylene; m-Dimethylbenzene; m-Xylol; 1,3-Dimethylbenzene; 1,3-Xylene; 2,4-Xylene; m-Methyltoluene; meta-Xylene; NSC 61769; 1,3-dimethylbenzene (m-xylene); m-Xylène; m-Xilene
Related Products
8260 MegaMix Calibration Mix, 2000 µg/mL in P&T Methanol, 1 mL/ampul
Residual Solvents Class 2 – Mix A (2020 Rev), 0.35-22.5 mg/mL in DMSO (dimethylsulfoxide), 1 mL/ampul
New York Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit
New York Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul
DL152/06 Aromatic Compounds Standard, 1000 µg/mL, P&T Methanol, 1 mL/ampul
Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit
Michigan/Missouri Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul
502.2 VOA Calibration Kit #3 (200 µg/mL)
502.2 MegaMix Standard, 200 µg/mL, P&T Methanol, 1 mL/ampul
524.3 VOA MegaMix Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
524 Rev. 4.0 VOA Kit #2 (2000 µg/mL)
DW-VOC Standard #2, 200 µg/mL, P&T Methanol, 1 mL/ampul
MA VPH Matrix Spike Mix with Surrogate, 2500 µg/mL, P&T Methanol, 1 mL/ampul
PA DEP UST Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
Residual Solvents #1, 3000 µg/mL in N,N-Dimethylacetamide, 1 mL/ampul
European Pharmacopoeia/ICH Class 2 Mix A, Dimethyl Sulfoxide, 1 mL/ampul
Gasoline Range Organics Standard, P&T Methanol, 1 mL/ampul
MA VPH Standard with Surrogate Rev. 1.1 (July 2004), 10,000 µg/mL in P&T Methanol, 1 mL/ampul
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
PVOC Mix (California), 1000 µg/mL, P&T Methanol, 1 mL/ampul
VOA Calibration Mix #3, 2000 µg/mL, P&T Methanol, 1 mL/ampul
Gasoline Range Organics Standard, 1000 µg/mL, P&T Methanol, 1 mL/ampul
Residual Solvents Class 2 - Mix A, DMSO, 1 mL/ampul
PVOC/GRO Mix (Wisconsin), 1000 µg/mL, P&T Methanol, 1 mL/ampul
Application Chromatograms
Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
Determination Of Hydrocarbon Group Type in Gasoline on Rxi-1ms by GC-VUV (ASTM D8071)
PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Cumene (Isopropylbenzene) on Rtx-1
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
Impurities in
p-
Xylene on Stabilwax
Styrene on Stabilwax
Ethylbenzene on Stabilwax
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Aromatics on Rtx-DHA-100 (ASTM D6729-14)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Residual Solvents Class 2 - Mix A (2013 Rev) on Stabilwax (G16)
40 mL of Electronic Cigarette Vapor Collected on a Thermal Desorption Tube and Analyzed on Rtx-VMS
Residual Solvents Class 2 — Mix A on Rxi-624Sil MS (G43) by USP <467>
PAMS 57 Component Mix on Rtx-1 (105 m)
Cannabis Residual Solvents at 50 ppm Cutoff
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Aromatics (Benzene/Toluene/Xylene) on Rtx-200
Aromatics (Benzene/Toluene/Xylene) on MXT-WAX
Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2
Aromatics (Benzene/Toluene/Xylene) on Rtx-Wax
BTEX on Rtx-502.2
Volatile Organics (Canada) on Rtx-VMS
Volatile Organics TO-15 Volatiles on Rtx-1
Custom Solvents Mix on Stabilwax-MS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Alcohols and Acetates on Stabilwax-MS
Volatile Organics US EPA Method 8260B on Rtx-VMS
Reformate on Rtx-1
Alaska Method AK101AA on Rtx-5Sil MS (PID)
Alaska Method AK101AA on Rtx-5Sil MS (FID)
Crude Oil, Prudhoe Bay on Rtx-1
Gasoline Aromatics on Rtx-1
Petroleum Oxygenates on Stabilwax
Gasoline Aromatics on Rtx-1
EPA Method 524.2, Revision 4 Rtx-VMS
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
p-
and
m-
Xylenes in Gasoline by GCxGC on Rtx-DHA-150 and Stabilwax
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Styrene Impurities on Stabilwax
EPA Method 524.2 on Rtx-502.2
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
Wisconsin GRO Mix, plus C12 on Rtx-502.2
m-
and
p-
Xylene on Rtx-DHA-150
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Styrene Impurities Rtx-1701
Competitor Comparison: Class 2 - Mix A Residual Solvents for USP <467> Water-Soluble Articles
Aromatics on Rt-TCEP
Mass APH on Rxi-1ms
Aromatics, Aliphatics on 10 TCEP 100/120 Chromosorb PAW
Aromatics (Xylene Isomers plus Cumene) on 5 RT-1200/1.75 Bentone 34 on 100/120 Silcoport
Aromatics (Xylene Isomers /BTEX) on 5 Rt-1200/5 Bentone 34 on 100/120 Silcoport
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents (Class 2 - Mixture A) on Stabilwax (G16)
Ozone Precursors on Rtx-1
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Solvent Mixture on Rt-Q-BOND
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Residual Solvents (Class 2 - Mixture A) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix A Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)