Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
EZ
GC &
EZ
LC Online Software Suite
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Dodecane
CAS # 112-40-3
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
170.3348
Formula
C
12
H
26
Melting Point
-10--9 °C, 263.2-263.8 °K, 14-15 °F
Boiling Point
214-218 °C, 487-491 °K, 417-424 °F
Density
780.8 mg mL
−1
log P
6.821
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Dodecane; n-Dodecane; Adakane 12; Ba 51-090453; CH3(CH2)10CH3; Bihexyl; Dihexyl; n-Dodecane min; Duodecane; C12; Dodecan
Related Products
Application Chromatograms
Comparison of Chiral Test Mix on Rt-βDEXsm at 25 and 500 Injections
PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
Petroleum Hydrocarbons (TPH) on Rxi-1ms
TNRCC 1006 Retention Time Marker Mix on Rxi-5Sil MS
NJ DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
MA DEP EPH Aliphatics on Rxi-5Sil MS
NJ DEP EPH Aliphatics on Rxi-5Sil MS
MA DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Simulated Distillation on Rtx-1 SimDist DiatoSorb-WHP by ASTM D2887
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
DRO/ORO Calibration Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Diesel #2/Mineral Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
DRO/ORO Calibration Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Diesel #2/Mineral Oil Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard Mix on Rxi-1HT
PAMS 57 Component Mix on Rtx-1 (105 m)
Volatile Amine Test Mix on Rtx-Volatile Amine (60 m x 0.32 mm ID)
Lubricant (Synthetic) on Stabilwax
BTEX on Rtx-502.2
Solvent Mixture #1 on Rtx-1
Solvent Mixture #1 on Rtx-200
Solvent Mixture #1 on Stabilwax
Solvent Mixture #2 on Rtx-1
Solvent Mixture #2 on Rtx-200
Solvent Mixture #2 on Stabilwax
Solvent Mixture #3 on Rtx-1
Solvent Mixture #3 on Rtx-200
Reformate on Rtx-1
Crude Oil, Arabian Light on Rtx-1
Crude Oil, Prudhoe Bay on Rtx-1
Alcohols Stabilwax
Solvent Mixture #3 on Stabilwax
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
Amine Test Mix Rtx-35 Amine
Low Bleed, High Efficiency MXT-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Food Packaging Volatiles on Rtx-5MS
Wisconsin GRO Mix, plus C12 on Rtx-502.2
Petroleum Oxygenates on Rt-TCEP
Aromatics on Rt-TCEP
Hydrocarbons (C7-C42) on Rtx-1
Simulated Distillation (C5-C44) on Rtx-2887
Detailed Hydrocarbons Analysis Rtx-DHA-100
DRO Mix on Rtx-5
C10-C40 Alkanes on Rxi-5HT
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
n-Alkanes on Rtx-Mineral Oil
Mass APH on Rxi-1ms
n-
alkanes (C10-C40) on Rtx-Mineral Oil
NJDEP EPH Aliphatic Fraction on Rtx-5
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA