Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Triphenyl phosphate
CAS # 115-86-6
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
326.2831
Formula
C
18
H
15
O
4
P
Melting Point
48-50 °C
Boiling Point
244 °C 10 mm Hg
Density
1.184 g/mL
Solubility in Water
organic solvents
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Triphenyl phosphate; TPP; Phosphoric acid, triphenyl ester; Celluflex TPP; Disflamoll TP; Phenyl phosphate ((PhO)3PO); Phosflex TPP; Triphenoxyphosphine oxide; TP; Trifenylfosfat; Altal; Dymel; Kronitex TPP; Phenyl phosphate; Triphenyl phosphoric acid ester; NSC 57868; TPhP; Triphénylphosphate; Trifenilfosfato
Related Products
Triphenylphosphate Standard, 1000 µg/mL, Acetone, 1 mL/ampul
EPA Method 525.3 Surrogate Standard, 500 ug/mL ea. in Acetone, 1 mL/ampul
QuEChERS Internal Standard Mix for GC/NPD and LC/MS/MS Analysis, in Acetonitrile, 5 mL/ampul
Triphenylphosphate Standard, 20 µg/mL in Acetonitrile, 5 mL/ampul
Method 525.2 Surrogate Standard Mix, 1000 ug/mL, Acetone, 1 mL/ampul
AOAC QuEChERS Triphenylphosphate Solution, 2 µg/mL in acetonitrile:acetic acid (99:1), 5 mL/ampul
QuEChERS Internal Standard Mix for GC/MS Analysis, in Acetonitrile, 5 mL/ampul
Application Chromatograms
200+ Pesticides in Strawberry on Low-Pressure GC Column Kit
EPA Method 525.3 UCMR4 Standard on Rxi-5Sil MS at 10x the Method Reporting Limit (SIM Analysis)
EPA Method 525.3 UCMR4 Standard on Rxi-5Sil MS at Method Reporting Limit (SIM Analysis)
EPA Method 525.3 Internal and Surrogate Standards on Rxi-5Sil MS
EPA Method 525.3 ONP Calibration Standard (with 525.3 Internal and Surrogate Standards) on the Rxi-5Sil MS
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 OPP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
GCxGC-TOFMS Contour Plot of Unfortified Detoxification Tea
GCxGC-TOFMS Contour Plot Showing Potential Isobaric Interference with Acephate (m/z 136) in 1D Analysis
GCxGC-TOFMS Contour Plot of Unfortified Berry Tea
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
EPA Method 8140/8141/8141A Organophosphorus Pesticides on Rtx-35
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-1701
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-1
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-35
Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS
Organophosphorus Pesticides (European) on Rtx-CLPesticides
Organophosphorus Pesticides (European) on Rtx-CLPesticides
Organophosphorous Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides & Rtx-OPPesticides2
Semivolatiles on Rxi-5ms by EPA Method 525.2
Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS
Organophosphorus Pesticides by EPA Method 8140/8141/8141A on Rtx-CLPesticides
Organophosphorus Pesticides by US EPA Method 8140/8141/8141A on Rtx-CLPesticides2
Organophosphorus Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides2