EZGC & EZLC Online Software Suite

Bis(2-ethylhexyl) phthalate

CAS # 117-81-7

Compound Structure and Properties

Molecular Weight390.5561
FormulaC24H38O4
Melting Point-50 °C, 223 °K, -58 °F
Boiling Point385 °C, 658 °K, 725 °F
Data above sourced from: ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Bis(2-ethylhexyl) phthalate; Bisoflex 81; Compound 889; Di(ethylhexyl) phthalate; Di(2-ethylhexyl) phthalate; Dioctyl phthalate; DEHP; DOP; Ethylhexyl Phthalate; Eviplast 80; Eviplast 81; Fleximel; Flexol DOP; Kodaflex DOP; Octoil; Octyl phthalate; Palatinol AH; Pittsburgh PX-138; Sicol 150; Staflex DOP; Truflex DOP; Vestinol AH; Vinicizer 80; Witcizer 312; 2-Ethylhexyl phthalate; Dioctyl-o-benzenedicarboxylate; di-iso-Octyl phthalate; Bis(ethylhexyl) phthalate; Bisoflex DOP; Celluflex DOP; Di(2-ethylhexyl) o-phthalate; Di-sec-octyl phthalate; Flexol plasticizer DOP; Hercoflex 260; NCI-C52733; Polycizer 162; PX-138; RC plasticizer DOP; Behp; DAF 68; Di(2-ethylhexyl)orthophthalate; Ergoplast fdo; Good-rite gp 264; Hatcol dop; Mollan O; Nuoplaz dop; Platinol ah; Platinol dop; Rcra waste number U028; Reomol dop

Related Products

8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
SVOC MegaMix 100 Kit, 1 mL/ampul; 3 ampuls/kit
8270/Appendix IX Kit
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
606 Calibration Mix, Phthalate Esters, 2000 µg/mL, Methanol, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
Method 525.2 Semivolatile Mix (revised), Acetone, 1 mL/ampul
CLP 04.1 B/N MegaMix Standard Kit
506 Calibration Mix, 1000 µg/mL, isooctane, 1 mL/ampul
CLP GPC Calibration Mix, Methylene Chloride, 5 mL/ampul

Application Chromatograms

Comparison of Conventional and LPGC-MS Analysis of EPA Regulated Phthalates
Conventional GC-MS Analysis of Phthalates on Rxi-35Sil MS
Fast GC-MS Analysis of Phthalates on LPGC Rxi-35Sil MS
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS