Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Phenanthrene-d10%20(IS)
CAS # 1517-22-2
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
188.2908
Formula
C
14
D
10
Data above sourced from:
ChemSpider
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Phenanthrene-D10; Phenanthrene, perdeutero-; [2H10]Phenanthrene; Phénanthrène-d10; Fenantrene-d10
Related Products
SV Internal Standard Mix, 4000 µg/mL, Methylene Chloride, 1 mL/ampul
Method 525.2 Internal Standard Mix, 1000 µg/mL, Acetone, 1 mL/ampul
EPA Method 525.3 PAH IS Mix, 500 µg/mL ea. in Acetone, 1 mL/ampul
SV Internal Standard Mix, 2000 µg/mL, Methylene Chloride, 1 mL/ampul, 15-pk.
SV Internal Standard Mix, 4000 µg/mL, Methylene Chloride, 1 mL/ampul, 15-pk.
Phenanthrene-d10 Standard, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
SV Internal Standard Mix, 2000 µg/mL, Methylene Chloride, 1 mL/ampul, 25-pk.
Revised SV Internal Standard Mix, 4000 µg/mL, Methylene Chloride, 1 mL/ampul
SV Internal Standard Mix, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
SV Internal Standard Mix, 4000 µg/mL, Methylene Chloride, 1 mL/ampul, 25-pk.
Revised SV Internal Standard Mix, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
Application Chromatograms
Semivolatiles on Rxi-SVOCms
Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar on Rxi-SVOCms (SIM)
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven
EPA Method 530 UCMR4 Standard at 10x the Method Reporting Limit on Rtx-1701 (SIM)
EPA Method 530 UCMR4 Standard at Method Reporting Limit on Rtx-1701 (SIM)
EPA Method 530 UCMR4 Standard at 10x the Method Reporting Limit on Rxi-5Sil MS (SIM)
EPA Method 530 UCMR4 Standard at Method Reporting Limit on Rxi-5Sil MS (SIM)
EPA Method 525.3 UCMR4 Standard on Rxi-5Sil MS at 10x the Method Reporting Limit (SIM Analysis)
EPA Method 525.3 UCMR4 Standard on Rxi-5Sil MS at Method Reporting Limit (SIM Analysis)
EPA Method 525.3 Internal and Surrogate Standards on Rxi-5Sil MS
EPA Method 525.3 ONP Calibration Standard (with 525.3 Internal and Surrogate Standards) on the Rxi-5Sil MS
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 OPP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
Nonylphenol, Bisphenol A, 4-
tert
-Octylphenol, Nonylphenol Monoethoxylate, and Nonylphenol Diethoxylate on the Rxi-5Sil MS by ASTM D7065-11 (Constant Flow)
Select PAHs on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)
Semivolatiles on Rxi-5ms (Split Injection)
Nonylphenol, Bisphenol A, 4-
tert
-Octylphenol, Nonylphenol Monoethoxylate, and Nonylphenol Diethoxylate on Rxi-XLB by ASTM D7065-11
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH (30 m x 0.25 mm ID x 0.10 µm df )
NIST SRM 1975, Diesel Particulate Extract, on Rxi-PAH
Accelerated Solvent Extraction of NIST SRM 1941b, Organics in Marine Sediment, on Rxi-PAH
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Semivolatiles on Rxi-5ms by EPA Method 525.2
Minnesota Dept. of Agriculture List 1 Pesticides on Rxi-1ms
Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS
Polycyclic Aromatic Hydrocarbons by EPA 610 on Rxi-5ms
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS