Dichlorobenzene-D4
CAS # 3855-82-1
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
151.0266
Formula
C
6
D
4
Cl
2
Data above sourced from:
ChemSpider
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
1,4-Dichlorobenzene-D4; 1,4-Dichlorbenzol-D4
Related Products
SV Internal Standard Mix, 4000 ug/mL, Methylene Chloride, 1 mL/ampul
524.3 Internal Standard Mix 2000 ug/mL, P&T Methanol, 1 mL/ampul
8260A Internal Standards Mix, 2500 ug/mL, P&T Methanol, 1 mL/ampul
SV Internal Standard Mix, 4000 ug/mL, Methylene Chloride, 1 mL/ampul, 25-pk.
SV Internal Standard Mix, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
8260A Volatile Organics Kit (2000 ug/mL)
8260 Internal Standard Mix, 2500 ug/mL, P&T Methanol, 1 mL/ampul
Revised SV Internal Standard Mix, 4000 ug/mL, Methylene Chloride, 1 mL/ampul
SV Internal Standard Mix, 2000 ug/mL, Methylene Chloride, 1 mL/ampul, 25-pk.
L/C VOA Internal Standard Mix, 2500 ug/mL, P&T Methanol, 1 mL/ampul
Revised SV Internal Standard Mix, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
SV Internal Standard Mix, 2000 ug/mL, Methylene Chloride, 1 mL/ampul, 15-pk.
524.3 Internal Standard/Surrogate Mix 2000 ug/mL, P&T Methanol, 1 mL/ampul
SV Internal Standard Mix, 4000 ug/mL, Methylene Chloride, 1 mL/ampul, 15-pk.
8260 Volatile Organics Kit, (2000 ug/mL)
Application Chromatograms
Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Volatile Organics US EPA Method 8260B on Rtx-VMS
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Peak Shape Comparison of Early Eluting Semivolatiles Using Split (10:1) and Splitless Injection at 80 °C Oven Start Temp.
Minnesota Dept. of Agriculture List 1 Pesticides on Rxi-1ms
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Polycyclic Aromatic Hydrocarbons by EPA 610 on Rxi-5ms
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Semivolatiles CLP Method on Rtx-5MS