Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Triacontane
CAS # 638-68-6
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
422.8133
Formula
C
30
H
62
Data above sourced from:
ChemSpider
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Triacontane; n-Triacontane; C30; n-Triacontano-d62
Related Products
NJDEP EPH 10/08 Rev.2 Aliphatics Calibration Standard, 2000 µg/mL, Hexane:Carbon Disulfide (80:20), 1 mL/ampul
DRO/ORO Range Calibration Standard, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
Qualitative Retention Time Index Standard, In Hexane, 1 mL/ampul
n-Triacontane d62 Standard, 500 µg/mL, Methylene Chloride, 1 mL/ampul
Florida TPH Standard, 500 µg/mL, Hexane, 1 mL/ampul
Florida TRPH Standard (HC), 2000 µg/mL, Carbon Disulfide, 1 mL/ampul
Leaking Underground Storage Tank (LUST) Retention Time Standard, 25 µg/mL, Methylene Chloride, 1 mL/ampul
MA EPH Aliphatic Hydrocarbon Standard, 1000 µg/mL, Hexane, 1 mL/ampul
System Performance Test Standard Mixture of n-Alkanes, 50 µg/mL, Hexane, 1 mL/ampul
NJDEP EPH 10/08 Rev.2 Aliphatics Matrix Spike Mix, 200 µg/mL, Pentane, 5 mL/ampul
Connecticut ETPH Calibration Mix, Methylene Chloride, 1 mL/ampul
Standard Mixture of n-alkanes for System Performance Test, 50 µg/mL, Cyclohexane, 1 mL/ampul
NJDEP EPH 10/08 Rev.2 Aliphatics Fractionation Check Mix, 400 µg/mL, Hexane, 5 mL/ampul
MA Fractionation Check Mix, 25 µg/mL, Hexane, 1 mL/ampul
Application Chromatograms
Petroleum Hydrocarbons (TPH) on Rxi-1ms
NJ DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
MA DEP EPH Aliphatics on Rxi-5Sil MS
NJ DEP EPH Aliphatics on Rxi-5Sil MS
MA DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
Arabian Medium Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
South Louisiana Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 11 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
South Louisiana Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Iraqi Basrah Light Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 11 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 1 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 5 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 5 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 1 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Arabian Medium Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Iraqi Basrah Light Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard Mix on Rxi-1HT
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
C10-C40 Alkanes on Rxi-5HT
Low Bleed, High Efficiency MXT-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
n-
Alkanes on Rtx-Mineral Oil
Hydrocarbons (C7-C42) on Rtx-1
n-
alkanes (C10-C40) on Rtx-Mineral Oil
NJDEP EPH Aliphatic Fraction on Rtx-5