Chloroform
CAS # 67-66-3
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
119.3776
Formula
CHCl
3
Melting Point
-63.5 °C, 210 °K, -82 °F
Boiling Point
61.2 °C, 334 °K, 142 °F
Density
1.483 g/cm
3
Solubility in Water
0.8 g/100 mL (20 °C)
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Trichloromethane; Chloroform; Freon 20; Methane, trichloro-; R 20; Trichloroform; CHCl3; Formyl trichloride; Methane trichloride; Methenyl trichloride; Methyl trichloride; Chloroforme; Cloroformio; NCI-C02686; R 20 (refrigerant); Trichloormethaan; Trichlormethan; Triclorometano; Rcra waste number U044; TCM; UN 1888; NSC 77361; F 20; クロロホルム
Related Products
Application Chromatograms
New York Residual Solvents on Rxi-624Sil MS
Michigan/Missouri Residual Solvents on Rxi-624Sil MS
Analysis of VOCs and Odors in Drinking Water via HS-SPME Arrow-GC-MS
Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Cannabis Residual Solvents at 50 ppm Cutoff
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics US EPA CLP 04.1 on Rtx-VMS
Volatile Organics (Canada) on Rtx-VMS
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
Solvents on Rtx-1
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Solvents on Stabilwax
EDB/DBCP by EPA 504.1 on Rtx-CLPesticides & Rtx-CLPesticides2
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-200
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-5
EPA Method 524.2 on Rtx-502.2
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Solvent Mixture on Rt-S-BOND
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-Q-BOND
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Chlorinated Disinfection Byproducts, Chlorinated Solvents, and Halogenated Pesticides by EPA 551.1 on Rtx-1301
Residual Solvents (Class 2 - Mixture B) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix B Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS
Residual Solvents (Class 2 - Mixture B) on Stabilwax (G16)
Residual Solvents Rxi-624Sil MS
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Solvents on HayeSep Q
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatiles US EPA Method 624 on Rtx-624
Halogenated Hydrocarbons on Rt-Alumina BOND/CFC