Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
EZ
GC &
EZ
LC Online Software Suite
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Isobutane
CAS # 75-28-5
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
58.1222
Formula
C
4
H
10
Melting Point
-233--33 °C, 40-240 °K, -388--28 °F
Boiling Point
-13--9 °C, 260-264 °K, 8-16 °F
Density
2.51 mg mL
−1
(at 15 °C, 100 kPa)
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Isobutane; Propane, 2-methyl-; Trimethylmethane; 1,1-Dimethylethane; 2-Methylpropane; iso-C4H10; i-Butane; Isobutane mixtures; R 600a; tert-Butane; A 31; Methylpropane; Propane, 2-methyl-isobutane; UN 1969; A 31 (hydrocarbon)
Related Products
Application Chromatograms
New York Residual Solvents on Rxi-624Sil MS
Michigan/Missouri Residual Solvents on Rxi-624Sil MS
Residual Solvent Gases Standard
Separation of Hydrocarbons using Hydrogen Carrier Gas on the Rt-Alumina/MAPD
Separation of Neopentane from Other C4 Hydrocarbons on the Rt-Alumina/MAPD
PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
Refinery Gas on Rt-Q-BOND
Hydrocarbon Gases on Rt-Q-BOND
Hydrocarbon Gases on Rt-Q-BOND
Refinery Gas on Rtx-DHA-100 (ASTM D2163)
Refinery Gas on Rt-Alumina BOND/Na
2
SO
4
(ASTM D2163-14)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Alkylate Standard on Rtx-DHA 50 by Method D5134-13
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
PAMS 57 Component Mix on Rtx-1 (105 m)
Cannabis Residual Solvents at 50 ppm Cutoff
Reformate on Rtx-1
Butane Fuel on Rtx-1
Butane Fuel on Rtx-1
Propane Fuel on Rtx-1
1,3-Butadiene on Rt-Alumina BOND/MAPD (Purity Analysis)
Crude 1,3-Butadiene on Rt-Alumina BOND/MAPD
Light Hydrocarbons on Rt-Alumina BOND/MAPD
Natural Gas on Rt-Alumina BOND/Na
2
SO
4
Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND/KCl, Rtx-1
Refinery Gas on Rt-Alumina BOND (Na
2
SO
4
)
Gasoline Light Fractions on Rtx-DHA-150
Light Hydrocarbons on Rtx-DHA-150
Natural Gas (82 Methane) on Rtx-DHA-150
Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na
2
SO
4
Propane Camping Fuel on Rt-Alumina BOND/KCl
Refinery Gas on Rt-Alumina BOND/KCl
Refinery Gas on Rt-QS-BOND
Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na
2
SO
4
Propane Camping Fuel on Rt-Alumina BOND/Na
2
SO
4
Butane Lighter Fluid on Rt-Alumina BOND/Na
2
SO
4
Natural Gas on Rt-Alumina BOND/KCl
Ozone Precursors on Rtx-1
Refinery Gas C1 to C5 Using n-Octane on Res-Sil C Packing
Refinery Gas Using OPN on Res-Sil C Packing
Refinery Gas Calibration Standard on Refinery Gas Packed Column Set
Sulfur Compounds and Hydrocarbons on Rt-XLSulfur
Natural Gas #2 on Rt-QS-BOND
Refinery Gas #6 on Rt-QS-BOND
Refinery Gas on MXT-Alumina BOND/Na
2
SO
4
Butane Lighter Fluid Rt-Alumina BOND/KCl