2-Chlorophenol
CAS # 95-57-8
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
128.5563
Formula
C
6
H
5
ClO
Melting Point
9.4 °C
Boiling Point
174.9 °C
Density
1.2634 g/cm
3
at 20 °C
Solubility in Water
20 g/L at 20 °C
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Phenol, 2-chloro-; Phenol, o-chloro-; o-Chlorophenol; 2-Chlorophenol; 2-Hydroxychlorobenzene; o-Chlorphenol; Rcra waste number U048; 1-Chloro-2-hydroxybenzene; Chlorophenol; NSC 2870; o-Chlorophenic acid
Related Products
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
SVOC MegaMix 100 Kit, 1 mL/ampul; 3 ampuls/kit
DL152/06 Phenols Standard, 100 µg/mL, Methanol, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
8270/Appendix IX Kit
Semivolatiles MegaMix Standard, EPA Method 625, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Acid Matrix Spike Mix, 10,000 µg/mL, Methanol, 1 mL/ampul, 15-pk.
8270 Calibration Mix #1, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
Semivolatile Calibration Kit #3 (with Benzidine)
Phenol Calibration Mix, EPA 528, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
SV Calibration Mix #2, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
SOM01.1 SVOA MegaMix Standard, Revised, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
8040 Phenols Mix #2, 2000 µg/mL, Isopropanol, 1 mL/ampul
8270 Calibration Kit, 2000 µg/mL
SOM01.1 SVOA MegaMix Standard Kit
CLP 4.1 Phenols Calibration Mix, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
Acid Matrix Spike Mix, 10,000 µg/mL, Methanol, 1 mL/ampul
Acid Matrix Spike Mix, 7500 µg/mL, Methanol, 5 mL/ampul
Acid Matrix Spike Mix, 10,000 µg/mL, Methanol, 5 mL/ampul
Polar ISO Column Test Mix, 250 µg/mL ea. in 1,2-Dichloroethane, 1 mL/ampul
604 Calibration Mix, Phenols, 2000 µg/mL, Methanol, 1 mL/ampul
Application Chromatograms
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Phenols & Benzidines US EPA Methods 604 & 605 on Rtx-5
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Phenols and Benzidines by U.S. EPA Methods 604 and 605 on Rtx-5
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Amines & Phenols on Rtx-5 Amine
Peak Shape Comparison of Early Eluting Semivolatiles Using Split (10:1) and Splitless Injection at 80 °C Oven Start Temp.
Phenols by EPA Method 604 on Rtx-5
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS
Phenols by EPA 604 on MXT-5
Phenols by EPA Method 604 on Rtx-200