Compound Structure and Properties
Molecular Weight
213.1045
Formula
C
6
H
3
N
3
O
6
Melting Point
123.2 °C, 396 °K, 254 °F
Boiling Point
315 °C, 588 °K, 599 °F
Density
1.76 g/cm
3
Solubility in Water
330 mg/L
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
1,3,5-Trinitrobenzene; Benzene,1,3,5-trinitro-; s-Trinitrobenzene; syn-Trinitrobenzene; Trinitrobenzeen; Trinitrobenzene; Trinitrobenzol; TNB; Rcra waste number U234; 1,3,5-Trinitrobenzène
Related Products
8270/Appendix IX Kit
8330B Nitroaromatics and Nitramine Explosives by HPLC Mix, 1000 µg/mL, Acetonitrile, 1 mL/ampul
Nitroaromatics and Nitramine Explosives by LC, 1000 µg/mL, Acetonitrile, 1 mL/ampul
8095 Calibration Mix A, 1000 µg/mL, Acetonitrile, 1 mL/ampul
8270 Calibration Mix #4, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
8330 Calibration Standard #1, 1000 µg/mL, Acetonitrile, 1 mL/ampul
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
8270 Calibration Kit, 2000 µg/mL
Appendix IX Mix #2, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
1,3,5-Trinitrobenzene Standard, 1000 µg/mL, Acetonitrile, 1 mL/ampul
Application Chromatograms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
Explosives on Raptor ARC-18 by EPA Method 8330B
Explosives on Raptor Biphenyl by EPA Method 8330B
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Aromatics on Raptor Biphenyl
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Explosives by EPA 8330B on Ultra C8 with Trident Direct Guard Column
Explosives by EPA 8330B on Ultra Aromax with Trident Direct Guard
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Explosives by U.S. EPA Method 8095 Rxi-5ms with PTV On-Column Liner
Improve Sensitivity with Larger Injection Volumes using a PTV On-Column Liner
Explosives by EPA Method 8095 on Rtx-TNT
Explosives US EPA Method 8095 Rtx-TNT2