Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
4-Nitrophenol
CAS # 100-02-7
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
139.1088
Formula
C
6
H
5
NO
3
Melting Point
113–114 °C
Boiling Point
279 °C, 552 °K, 534 °F
Solubility in Water
10 g/L (15 °C)
11.6 g/L (20 °C)
16 g/L (25 °C)
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Phenol, 4-nitro-; Phenol, p-nitro-; p-Hydroxynitrobenzene; p-Nitrophenol; Niphen; 4-Hydroxynitrobenzene; 4-Nitrophenol; NCI-C55992; Paranitrofenol; Paranitrofenolo; Paranitrophenol; 4-Nitrofenol; p-Nitrofenol; Rcra waste number U170; 1-Hydroxy-4-nitrobenzene; Mononitrophenol; PNP; 4-Nitrophénol; 4-Nitrofenolo
Related Products
8270 MegaMix Standard, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
SOM01.1 SVOA MegaMix Standard, Revised, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
Phenol Calibration Mix, EPA 528, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
SOM01.1 SVOA MegaMix Standard Kit
SV Calibration Mix #2, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
Chlorinated Acids by LC, Mix B, 1000 ug/mL, Acetonitrile, 1 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
8270/Appendix IX Kit
8270 Calibration Kit, 2000 ug/mL
500/8000 Herbicide Mix #4 Free Acid Form, 200 ug/mL, Methanol, 1 mL/ampul
Acid Matrix Spike Mix, 10,000 ug/mL, Methanol, 1 mL/ampul, 15-pk.
SV System Performance Check Mix (SPCC), 2000 ug/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
Acid Matrix Spike Mix, 10,000 ug/mL, Methanol, 1 mL/ampul
Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
CLP 4.1 Phenols Calibration Mix, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
Acid Matrix Spike Mix, (4/89 SOW), 2000 ug/mL, Methanol, 1 mL/ampul
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
8040 Phenols Mix #1, 2000 ug/mL, Isopropanol, 1 mL/ampul
4-Nitrophenol Standard, 1000 µg/mL, Methanol, 1 mL/ampul
SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit
8270 Calibration Mix #1, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
604 Calibration Mix, Phenols, 2000 ug/mL, Methanol, 1 mL/ampul
Application Chromatograms
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Phenols & Benzidines US EPA Methods 604 & 605 on Rtx-5
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Phenols and Benzidines by U.S. EPA Methods 604 and 605 on Rtx-5
Herbicides (Phenoxyacid Mix B) on Ultra Aqueous C18
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Phenoxyacid Herbicides on Ultra Cyano (Overlay)
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Phenoxyacid Herbicides on Ultra Aqueous C18
Phenols by EPA Method 604 on Rtx-5
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS
Phenols by EPA 604 on MXT-5
Phenols by EPA Method 604 on Rtx-200