Pyridine
CAS # 110-86-1
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
79.0999
Formula
C
5
H
5
N
Melting Point
-41.6 °C, 232 °K, -43 °F
Boiling Point
115.2 °C, 388 °K, 239 °F
Density
0.9819 g/mL
Solubility in Water
Miscible
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Pyridine; Azabenzene; Azine; NCI-C55301; Piridina; Pirydyna; Pyridin; Rcra waste number U196; Pyr; Pyridine - headspace - from sample -; CP 32; NSC 406123; UN 1282
Related Products
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
Residual Solvents Class 2 - Mix B, DMSO (Lower Concentrations), 1 mL/ampul
Amine 900 Test Mix, Methanol:Methylene Chloride (50:50), 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
TCLP B/N Method 1311 Standard, 2000 µg/mL, Acetone, 1 mL/ampul
8270 Calibration Mix #2, 2000 µg/mL, Methylene Chloride:Methanol (85:15), 1 mL/ampul
Residual Solvents Class 2 - Mix B, DMSO, 1 mL/ampul
Pyridine Standard, 2000 µg/mL, P&T Methanol, 1 mL/ampul
Amine Column Test Mix (GC), Methylene Chloride:Methanol (1:1), 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
Pyridine Standard, 1 mg/mL, DMSO, 1 mL/ampul
Inter-Polar Column Test Mix, Methylene Chloride, 1 mL/ampul
8270 Calibration Kit, 2000 µg/mL
Volatile Amine Column Test Mix, Methanol:Methylene Chloride (50:50), 1 mL/ampul
European Pharmacopoeia/ICH Class 2 Mix B, Revised, Prepared in Water:Dimethyl Sulfoxide (80:20), 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
SVOC MegaMix 100 Kit, 1 mL/ampul; 3 ampuls/kit
8270/Appendix IX Kit
Application Chromatograms
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Balanced Rxi-SVOCms Column Chemistry Produces Symmetrical Peaks and Stable Retention Times as Mass on Column Varies
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Volatile Amine Test Mix on Rtx-Volatile Amine (60 m x 0.32 mm ID)
Substituted Pyridine on Rtx-1701
Substituted Pyridine on Stabilwax
1,4-Dioxane, 2,4-Dinitrophenol, and Pyridine US EPA Method 8270D on Rxi-1ms
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Solvents (Nitrogen Containing) on Rtx-1701
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Uracil, Pyridine, and Phenol on Ultra Aqueous C18
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Amine Test Mix Rtx-35 Amine
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
Amines & Phenols on Rtx-5 Amine
An Rxi-5ms column provides the most symmetric peak for the basic compound pyridine
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents (Class 2 - Mixture B) on Stabilwax (G16)
Residual Solvents Rxi-624Sil MS
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Solvent Mixture on Rt-Q-BOND
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Residual Solvents (Class 2 - Mixture B) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix B Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS