Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Diphenylamine
CAS # 122-39-4
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
169.2224
Formula
C
12
H
11
N
Melting Point
53 °C (326 K)
Boiling Point
302 °C (575 K)
Density
1.2 g/cm³
Solubility in Water
Slightly
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Diphenylamine; Benzenamine, N-phenyl-; Anilinobenzene; Benzene, (phenylamino)-; DFA; DPA; N-Phenylaniline; N-Phenylbenzeneamine; Diphenylamine indicator; Aniline, N-phenyl-; Benzene, anilino-; Big Dipper; C.I. 10355; Diphenpyramide; N-Phenylbenzenamine; N,N-Diphenylamine; No scald; Phenylaniline; Scaldip; Z-876; Deccoscald 282; Difenylamin; N-Fenylanilin; No scald dpa 283; OA-505
Related Products
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
GC Multiresidue Pesticide Standards Kit
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
DL152/06 Aromatic Amines Standard, 100 µg/mL, Methanol, 1 mL/ampul
CLP 04.1 B/N MegaMix Standard, Revision 2, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 B/N Calibration Check Mix, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
SOM01.1 SVOA MegaMix Standard, Revised, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
SOM01.1 SVOA MegaMix Standard Kit
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
SVOC MegaMix 100 Kit, 1 mL/ampul; 3 ampuls/kit
8270 Calibration Mix #2, 2000 µg/mL, Methylene Chloride:Methanol (85:15), 1 mL/ampul
GC Multiresidue Pesticide Standard #3 Organonitrogen Compounds, 100 µg/mL, Toluene/Acetonitrile (99:1), 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
Semivolatiles MegaMix Standard, EPA Method 625, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
CLP 04.1 B/N MegaMix Standard Kit, 2 ampuls/kit
8270/Appendix IX Kit
8270 Calibration Kit, 2000 µg/mL
Application Chromatograms
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Nitrosamines on Rxi-624Sil MS
200+ Pesticides in Strawberry on Low-Pressure GC Column Kit
GC Multiresidue Pesticide Standard #3-ONP on Rxi-5ms by GC-MS
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Nitrosamines by U.S. EPA Method 607 on Rtx-5
Incurred Pesticides in Red Bell Pepper QuEChERS Extract on Ultra Aqueous C18
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatiles CLP Method on Rtx-5MS