Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Ethyl acetate
CAS # 141-78-6
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
88.1051
Formula
C
4
H
8
O
2
Melting Point
-83.6 °C, 190 °K, -118 °F
Boiling Point
77.1 °C, 350 °K, 171 °F
Density
0.897 g/cm³
Solubility in Water
8.3 g/100 mL (20 °C)
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Ethyl Acetate; Acetic acid, ethyl ester; Acetic ether; Acetidin; Acetoxyethane; Ethyl acetic ester; Ethyl ethanoate; Vinegar naphtha; CH3COOC2H5; Aethylacetat; Essigester; Ethyle(acetate d'); Etile(acetato di); Ethylacetaat; Ethyle; Ethylester kyseliny octove; Etile; Rcra waste number U112; Ethyl ester of acetic acid; Acetic ester; Ethyle (acetate d'); Etile (acetato di); 1-Acetoxyethane; NSC 70930; ac. acetic ethyl ester; EtOAc; Ethylacetat; UN 1173; UN 1173
Related Products
Residual Solvents Class 3 – Mix A (2020 Rev), 5000 µg/mL in N,N-DMF (N,N-dimethylformamide), 1 mL/ampul
Michigan/Missouri Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul
New York Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit
New York Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul
Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit
Residual Solvents Class 3 - Mix A, 5000 µg/mL each in N,N-Dimethylformamide, 1 mL/ampul
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
8260B Acetates Mix, 2000 µg/mL, P&T Methanol, 1 mL/ampul
Volatile MegaMix II, 2000-10,000 µg/mL in P&T Methanol, 1 mL/ampul
Residual Solvents #1, 3000 µg/mL in N,N-Dimethylacetamide, 1 mL/ampul
Q-BOND and U-BOND Column Test Mix, 0.1% Vol/Vol ea. in Heptane, 1 mL/ampul
8260 Acetate Mix, 2000 µg/mL, P&T Methanol, 1 mL/ampul
Blood Alcohol Mix, Resolution Control Standard, 0.100 g/dl, Water, 1 mL/ampul
Application Chromatograms
Rye Whiskey on Rtx-1301
Rye Whiskey on Rtx-1301
Marsala on Rtx-1301
Irish Whiskey on Rtx-1301
Sherry on Rtx-1301
Brandy on Rtx-1301
Rum on Rtx-1301
Custom Beverage Analysis Mix on Rtx-1301
Irish Whiskey on Rtx-1301
Brandy on Rtx-1301
New York Residual Solvents on Rxi-624Sil MS
Michigan/Missouri Residual Solvents on Rxi-624Sil MS
Expanded List of Volatile Organics by Purge & Trap on Rtx-VMS
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
USP <467> Residual Solvents Class 3 MIx A on Rxi-624Sil MS
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Electronic Cigarette Liquid on Rtx-VMS (GC-MS)
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Solvents on Rtx-1701
Custom Solvents Mix on Stabilwax-MS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Alcohols and Acetates on Stabilwax-MS
Volatile Organics US EPA Method 8260B on Rtx-VMS
Alcohols Rtx-5
Alcohols Rtx-Volatiles
Solvents on Rtx-1
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Volatile Solvents on Rtx-Wax
Solvents on Rtx-Volatiles
Solvents on Rtx-5
Solvents on Stabilwax
Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS
Rum on CarboBlack B
Scotch on CarboBlack B
Flavor Volatiles on Stabilwax
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Restek PLOT Column Technology Assures Stable Performance Even After 500 Pressure Cycles
Solvents on MXT-Q-BOND
Volatile Organics by EPA 8260B on Rtx-VMS
MXT-Q-BOND Columns are Highly Stable; Pressure Pulsing does not Create Particles or Alter Retention Times
Volatile Organics by EPA 8260B on Rtx-VMS
Solvents on Polar Rt-QPLOT
Mushroom Aroma (Synthetic) on Stabilwax
Solvent Mixture on Rt-Q-BOND
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2