Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Benzo(ghi)perylene
CAS # 191-24-2
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
276.3307
Formula
C
22
H
12
Melting Point
278 °C, 551 °K, 532 °F
Boiling Point
500 °C, 773 °K, 932 °F
Density
1.378 g/cm
3
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Benzo[ghi]perylene; Benzo-1,12-perylene; 1,12-Benzoperylene; 1,12-Benzperylene; Benzo(ghi)pérylène; Benzo(ghi)perilene
Related Products
8270 MegaMix Standard, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
NJDEP EPH 10/08 Rev.2 Aromatics Calibration Standard, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
MA Fractionation Check Mix, 25 ug/mL, Hexane, 1 mL/ampul
WA EPH Aromatic Hydrocarbon Mix, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
Semivolatile Calibration Kit #3 (with Benzidine)
Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
NJDEP EPH 10/08 Rev.2 Aromatics Matrix Spike Mix, 200 ug/mL, Acetone:Toluene (50:50), 5 mL/ampul
EPA Method 525.3 PAH Cal Standard, 500 ug/mL ea. in Acetone, 1 mL/ampul
EPA Method 8310 Quality Control Check, Acetonitrile, 1 mL/ampul
WA EPH Fractionation Check Mix, 25 ug/mL, Hexane, 1 mL/ampul
610 PAH Calibration Mix B, Methylene Chloride:Methanol 50:50, 1 mL/ampul
WA EPH Aromatic Hydrocarbon Standard, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
CLP 04.1 B/N MegaMix Standard, Revision 2, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit
SOM01.1 SVOA MegaMix Standard Kit
EU 15+1 PAH Standard 100 µg/mL, Toluene, 1 mL/ampul
EPA Method 8310 PAH Mix 500 μg/mL, Acetonitrile/Toluene (92:8), 1 mL/ampul
Benzo[g,h,i]perylene Standard, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
610 PAH Calibration Mix A, Methylene Chloride,1 mL/ampul
CLP 04.1 B/N MegaMix Standard Kit
Method 525.2 Semivolatile Mix (revised), Acetone, 1 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
Application Chromatograms
Comparison: Semivolatiles on Narrow-Bore Rxi-SVOCms - IV Liner Article Figure 5
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Priority PAH Pollutants on Rxi-SVOCms (SIM)
Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar on Rxi-SVOCms (SIM)
Semivolatiles Analysis on Rxi-SVOCms
MA DEP EPH Aromatics on Rxi-5Sil MS
NJ DEP EPH Aromatics on Rxi-5Sil MS
MA DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
NJ DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
Resolution of Indeno[123-cd]pyrene from Dibenz Anthracene Isomers on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)
Select PAHs on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)
Semivolatiles on Rxi-5ms (Split Injection)
EPA 8310 PAHs on Pinnacle II PAH by LC-UV
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH (30 m x 0.25 mm ID x 0.10 µm df )
NIST SRM 1975, Diesel Particulate Extract, on Rxi-PAH
Accelerated Solvent Extraction of NIST SRM 1941b, Organics in Marine Sediment, on Rxi-PAH
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH
Detailed Analysis of Polycyclic Aromatic Hydrocarbons (PAHs) in Creosote Oil on Rxi-PAH
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)
PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
NIST SRM 2260a PAH Mix on Rxi-PAH
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-CLPesticides2
Polynuclear Aromatic Hydrocarbons US EPA Method 8100 on MXT-5
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-5
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-440
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
PAHs and PCB Congeners on Rxi-XLB
EU 15+1 PAH Mix on Pinnacle DB PAH
EU 15+1 PAHs on Pinnacle II PAH (UV/Vis)
EPA 8310 PAH Mix on Pinnacle II PAH (FLD)
EPA 8310 PAH Mix on Pinnacle DB PAH
EU 15+1 PAHs on Pinnacle II PAH (FLD)
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Polycyclic Aromatic Hydrocarbons on Rtx-50
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS
Polycyclic Aromatic Hydrocarbons on Rxi-17
Polycyclic Aromatic Hydrocarbons on Rxi-17 column
Polycyclic Aromatic Hydrocarbons on Rxi-17 (15m x 0.25mm x 0.25µm)
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
Polycyclic Aromatic Hydrocarbons by EPA Method 610 on Rxi-5ms
Semivolatiles on Rxi-5ms by EPA Method 525.2
EPA Method 610 Polycyclic Aromatic Hydrocarbons on Pinnacle DB PAH
QuEChERS Extract of NIST SRM 2974a Freeze-Dried Mussel Tissue (GCxGC contour plot)
NJDEP EPH Aromatics on Rtx-5
Polycyclic Aromatic Hydrocarbons by EPA 610 on Rxi-5ms
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS