Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Benzyl butyl phthalate
CAS # 85-68-7
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
312.3597
Formula
C
19
H
20
O
4
Melting Point
-35 °C, 238 °K, -31 °F
Boiling Point
370 °C, 643 °K, 698 °F
Density
1.1 g cm
−3
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Benzyl butyl phthalate; Butyl benzyl phthalate; Palatinol BB; Santicizer 160; Sicol; Sicol 160; Unimoll BB; n-Butyl benzyl phthalate; NCI-C54375; BBP; Benzyl n-butyl phthalate; 1-Benzyl 2-butyl phthalate; Phthalic acid, benzyl butyl ester
Related Products
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
SVOC MegaMix 100 Kit, 1 mL/ampul; 3 ampuls/kit
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
CLP 04.1 B/N MegaMix Standard Kit, 2 ampuls/kit
8270 Calibration Kit, 2000 µg/mL
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
606 Calibration Mix, Phthalate Esters, 2000 µg/mL, Methanol, 1 mL/ampul
EPA Method 525.3 PAH Cal Standard, 500 µg/mL ea. in Acetone, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
506 Calibration Mix, 1000 µg/mL, isooctane, 1 mL/ampul
8270/Appendix IX Kit
EPA Method 8061A Phthalate Esters Mixture, 1000 µg/mL in Hexane:Acetone (80:20), 1 mL/ampul
Method 525.2 Semivolatile Mix (revised), Acetone, 1 mL/ampul
SOM01.1 SVOA MegaMix Standard Kit
SV Calibration Mix #3, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
Semivolatile Calibration Kit #3 (with Benzidine)
Semivolatiles MegaMix Standard, EPA Method 625, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Calibration Mix #4, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
SOM01.1 SVOA MegaMix Standard, Revised, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
CLP 04.1 B/N MegaMix Standard, Revision 2, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Application Chromatograms
EPA 8270E Semivolatiles on RMX-5Sil MS by GC-MS/MS (Shimadzu Chromatogram)
Semivolatiles on RMX-5Sil MS by 8270D (GC-MS in SIM Mode)
HJ 834-2017 Volatiles and Semivolatiles on RMX-5Sil MS (Optimized Conditions)
Phthalates on Raptor Inert Biphenyl
Comparison of Conventional and LPGC-MS Analysis of EPA Regulated Phthalates
Conventional GC-MS Analysis of Phthalates on Rxi-35Sil MS
Fast GC-MS Analysis of Phthalates on LPGC Rxi-35Sil MS
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
EPA and EU Phthalates on Rtx-CLPesticides2
EPA and EU Phthalates on Rtx-50
EPA and EU Phthalates on Rtx-CLPesticides
EPA and EU Phthalates on Rxi-5ms
Phthalates on Rxi-XLB (Extended List)
EPA and EU Phthalates on Rxi-XLB
EPA and EU Phthalates on Rtx-440
Phthalates (50 µg/mL) on Rtx-440 (Extended List, Full Scan Mode)
EPA and EU Phthalates on Rxi-35Sil MS
EPA Method 8061A Phthalates on Rtx-440
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
EPA Method 8060 Phthalate Esters on Rtx-5 (Direct Injection)
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Phthalate Esters by U.S. EPA Method 606 on MXT-5
Phthalate Esters by U.S. EPA Method 606 on Rtx-5
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Semivolatiles on Rxi-5ms by EPA Method 525.2
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS