Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Carbazole
CAS # 86-74-8
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
167.2066
Formula
C
12
H
9
N
Melting Point
246.3 °C
Boiling Point
354.69 °C
Density
1.301g/cm^3
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Carbazole; 9H-Carbazole; Dibenzopyrrole; Dibenzo[b,d]pyrrole; Diphenylenimine; 9-Azafluorene; Diphenylenimide; Diphenyleneimine; usaf ek-600; Skf 20091; Carbazolo
Related Products
8270 MegaMix Standard, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
Carbazole Standard, 1000 µg/mL, Methanol, 1 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
SOM01.1 SVOA MegaMix Standard, Revised, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
8270/Appendix IX Kit
SOM01.1 SVOA MegaMix Standard Kit
Carbazole Standard, 1000 µg/mL, Methylene Chloride (Methanol free), 1 mL/ampul
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
CLP 04.1 B/N MegaMix Standard, Revision 2, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
SV Calibration Mix #4, 2000 ug/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit
Semivolatile Calibration Kit #3 (with Benzidine)
CLP 04.1 B/N MegaMix Standard Kit
8270 Matrix Spike Mix, 200 ug/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
Application Chromatograms
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Phenylurea Herbicides on Ultra Cyano
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS