Pro
EZ
GC 色谱模拟软件
Pro
EZ
LC 色谱模拟软件
EZ
GC 方法转换器 & 和流量计算器
Pro
EZ
LC 方法转换器
Skip to Content
EZ
GC &
EZ
LC 在线软件组
我的账户
创建账户
登录
Restek Home
Pro
EZ
GC 色谱模拟软件
Pro
EZ
LC 色谱模拟软件
EZ
GC 方法转换器 & 和流量计算器
Pro
EZ
LC 方法转换器
Endrin aldehyde
CAS # 7421-93-4
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
380.9093
Formula
C
12
H
8
Cl
6
O
Data above sourced from:
ChemSpider
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
Endrin aldehyde; Endrine aldéhyde; Endrin aldeide
Related Products
GC Multiresidue Pesticide Standards Kit
Organochlorine Pesticide Resolution Check Mix (with Surrogates), Hexane:Toluene (90:10), 1 mL/ampul
508.1 Pesticides Kit
GC Multiresidue Pesticide Standard #2 Organochlorine Compounds, 100 µg/mL, Toluene, 1 mL/ampul
Organochlorine Pesticide Mix AB #3, 2000 µg/mL, Hexane:Toluene (1:1), 1 mL/ampul
Pesticide Standard Mix B, Hexane:Toluene (90:10), 1 mL/ampul
Pesticide Standard Mix B w/Surrogates, 3/90 SOW, Hexane/Toluene (90:10), 1 mL/ampul
Endrin Aldehyde Standard, 1000 µg/mL in acetone, 1 mL/ampul
608 Calibration Mix, 200 µg/mL, Hexane:Toluene1:1, 1 mL/ampul
508.1 Calibration Mix #1, 500 µg/mL, Ethyl Acetate, 1 mL/ampul
608 Pesticides Kit
SV Calibration Mix #6, 2000 µg/mL, Toluene:Hexane (1:1), 1 mL/ampul
Organochlorine Pesticide Mix AB #2, Hexane:Toluene (1:1), 1 mL/ampul
Organochlorine Pesticide Mix AB #1, 200 µg/mL, Hexane:Toluene (1:1), 1 mL/ampul
Application Chromatograms
Comparison of Conventional vs. LPGC-MS Pesticides Analysis
200+ Pesticides in Strawberry on Low-Pressure GC Column Kit
Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set
Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set
GC Multiresidue Pesticide Standard #2-OCP on Rxi-5ms by GC-MS
7-Minute Analysis of Organochlorine Pesticides (EPA Method 8081) on Rtx-CLPesticides and Rtx-CLPesticides2 Using Hydrogen
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides
Organochlorine Pesticides US EPA Method 8081 on Rtx-1701
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2 (0.32mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides (0.32mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2 (0.53mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides (0.53mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-35
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2
Organochlorine Pesticides Fast Analysis Conditions on Rtx-CLPesticides & Rtx-CLPesticides2 (dual column analysis)
Recovery of Chlorinated Pesticides from Solvent Extracts Using CarboPrep 90
Comparison: Florisil SPE Cleanup of Blank Extract and EPA 8081 Pesticides Extract on Rtx-CLPesticides2
Florisil SPE Cleanup of EPA 8081 Pesticides on Rtx-CLPesticides2
Organochlorine Pesticides, PCBs, and BFRs on Rxi-XLB and Rxi-17Sil MS (GCxGC-ECD)
Organochlorine Pesticides by U.S. EPA Method 8081A on Rtx-CLPesticides2 (dual column w/ Rtx-440)
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-50
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-5
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-CLPesticides2
Organochlorine Pesticides by EPA Method 508 on Rtx-5
Organochlorine Pesticide Mix AB #2 on Rtx-CLPesticides2 and Rtx-CLPesticides (0.53 mm ID column set)
Method 8081B Chlorinated Pesticides on Rtx-CLPesticides2
Organochlorine Pesticides by EPA Method 8081A on Rtx-440 (dual column w/ Rtx-CLPesticides2)
Organochlorine Pesticides by EPA Method 8081B on Rtx-CLPesticides/Rtx-CLPesticides2 (extended list)
Organochlorine Pesticides by EPA 8081A on Rtx-CLPesticides & Rtx-CLPesticides2
Organochlorine Pesticides on Rtx-CLPesticides Columns (0.18 mm ID column set)
Organochlorine Pesticide Mix AB #2 on Rtx-CLPesticides2 and Rtx-CLPesticides (0.32 mm ID column set)
Pesticides & Herbicides U.S. EPA Method 508.1 Rtx-CLPesticides & Rtx-CLPesticides2
Chlorinated Disinfection Byproducts, Chlorinated Solvents, and Halogenated Pesticides by EPA 551.1 on Rtx-1301
Chlorinated Pesticide Residues in Olive Oil Rtx-CLPesticides2
Organochlorine Pesticides on Rtx-CLPesticides2
Organochlorine Pesticides on Rtx-CLPesticides
Organochlorine Pesticide Mix AB #2 Rtx-CLPesticides and Rtx-CLPesticides2 (0.25 mm ID column set)